Filter Results By:

Products

Applications

Manufacturers

High Voltage

electric power transmission is > 35,000 volts and for safety AC > 1000 and DC > 1,500. AKA: HV

See Also: High Voltage Switching, High Voltage Meters, High Voltage Detectors, High Voltage Programmable Power Supplies, HV


Showing results: 2131 - 2145 of 2457 items found.

  • PXI-6230, 8 AI (16-Bit, 250 kS/s), 4 AO, 6 DI, 4 DO, Bank-Isolated, PXI Hybrid, Multifunction I/O

    779616-01 - NI

    8 AI (16-Bit, 250 kS/s), 4 AO, 6 DI, 4 DO, Bank-Isolated, PXI Multifunction I/O Module—The PXI‑6230 is a bank-isolated DAQ device designed for voltage I/O. It offers analog I/O, digital input, digital output, two 32‑bit counters, and digital triggering. The digital input and outputs are compatible with 5 V TTL/CMOS signals. It combines the safety and performance benefits of isolation with high-performance timing, amplification, and calibration technologies to offer accurate measurements and precise control. The PXI‑6230 is ideal for test, measurement, control, and design applications in environments with high voltages and electrical noise. You can use the PXI‑6230 to read from encoders, flow meters, and proximity sensors as well as control valves, pumps, and relays.

  • PXI-6232, 16 AI (16-Bit, 250 kS/s), 2 AO, 6 DI, 4 Sourcing DO, Bank-Isolated, PXI Multifunction I/O Module

    779618-01 - NI

    16 AI (16-Bit, 250 kS/s), 2 AO, 6 DI, 4 Sourcing DO, Bank-Isolated, PXI Multifunction I/O Module—The PXI‑6232 is a bank-isolated DAQ device designed for voltage I/O. It offers analog I/O, digital input, sourcing digital output, two 32‑bit counters, and digital triggering. The digital input and outputs are compatible with 24 V signals. It combines the safety and performance benefits of isolation with high-performance timing, amplification, and calibration technologies to offer accurate measurements and precise control. The PXI‑6232 is ideal for test, measurement, control, and design applications in environments with high voltages and electrical noise. You can use the PXI‑6232 to read from encoders, flow meters, and proximity sensors as well as control valves, pumps, and relays.

  • Low Phase Noise Amplifiers

    Pasternack Enterprises, Inc.

    Pasternack's low phase noise amplifiers cover select frequency bands ranging from 1.5 to 18 GHz with residual phase noise levels as low as -180 dBc/Hz @ 10 KHz offset. Additional performance specs include small signal gain ranging from 9 to 14 dB, with typical noise figure of 5.5 dB. Psat levels for these amplifiers range from +16 to +25 dBm with Output IP3 levels as high as +34 dBm. All models feature single DC voltage supplies and input/output RF ports are internally matched for 50 ohms with DC blocking capacitors. These compact module assemblies require no external components and are available in rugged Kovar metal drop-in packages that are gold-over-nickel-plated and support field replaceable SMA connectors. All models are EAR99 and guaranteed to meet MIL-STD-883 test conditions for hermeticity and temperature cycle.

  • Bench/System Multi-Range DC Power Supply With Digital Control, 3 Or 4 Outputs, 315 To 420W With/without Remote Interfaces

    MX Series - Aim-TTi

    Three or four high performance outputs each with full functionalityRange switching gives variable voltage/current combinationsShared power mode provides double power from a single outputLow output noise and ripple via linear final regulationHigh setting resolution of up to 1mV and 0.1mAVariable OVP and OCP trips on all outputs50 setting memories per output plus 50 linked memoriesSelectable voltage tracking (isolated tracking)Selectable current meter averagingSwitchable remote sense capabilityGraphic LCD provides simultaneous output meteringNumeric or spin-wheel control of all parametersIndividual or combined output on/off control with programmable delay sequencing.3U half-rack case for bench or rack mounting (4U rack kit accessory available)RS-232, USB and LAN (LXI) interfaces (P models)GPIB option (P models only)Duplicate power & sense terminals at rear (P models)

  • The Nanomotor®

    Klocke Nanotechnik

    The patented Nanomotor® is a piezo driven linear motor. It is a multifunctional basic part for many positioning and manipulation devices. It has a positioning stroke of up to more than a centimeter while operating with atomic resolution. The Nanomotor thus bridges eight orders of magnitude. The Nanomotor consists of a cylindrical housing and a slider with a free axial hole inside. It combines high resolution in the sub-nanometer range with a large positioning stroke. The Nanomotor utilizes a piezo tube for fine positioning and a shock wave produced by the same piezo tube for coarse movements. The small Nanomotor is half the size of a match stick. It can lift six times its own mass. Every point of its stroke can be reached with a speed of up to 1 mm/s. The Nanomotor also works in ultrahigh vacuum or even under water. It is driven by a PC card at a supply voltage of only ±15 volts.

  • Non-Contact H.V. Detector

    278 HP - Standard Electric Works Co., Ltd

    ● Protection class : IP65.● 3 LED indicators in a circle for easier viewing in any directions (360° LED indication).● 8 voltage settings : 240V, 2kV, 6kV, 11kV, 22kV, 33kV, 132kV, 275kV● Bright LED visual indication● Frequency range: 40~70Hz● Longer hood makes LED indicators more visible● Audible indication● Easy-to-prove method.● Self-test function● Power source : 1.5V "C" type battery × 3● High impact nylon casing.● Non-contact detection by proximity● Compatible with most hot sticks.● Lightweight, robust & compact.● Suitable for indoor and outdoor use.● Easy access to batteries.● Special ranges are available upon request. ● The maximum detection range can be 500kV.● Meets EN 61326-1 CISPR 11 EN 61000-4-2 EN 61000-4-3 EN 61000-4-8

  • Insulation Resistance Tester For PV (Judge Deterioration Point)

    MIS-PVS - MULTI MEASURING INSTRUMENTS Co., Ltd.

    The model MIS-PVS is an insulation resistance tester for the exclusive use in photovoltaic systems. The ordinary insulation resistance testers cannot make measurement properly during generation of PV systems. This instrument, however, can measure the insulation resistance simply by touching probe to the live line whether making generation or not. There are two ranges of PVH and PVL. PVH is for high voltage generation system (more than 500V and less than 1000V) and PVL is for the system less than 500V.

  • Insulation Resistance Tester For PV (4 Range)

    MIS-PV2 - MULTI MEASURING INSTRUMENTS Co., Ltd.

    The model MIS-PV2 is an insulation resistance tester for the exclusive use in photovoltaic systems. The ordinary insulation resistance testers cannot make measurement properly during generation of PV systems. This instrument, however, can measure the insulation resistance simply by touching probe to the live line whether making generation or not. There are two ranges of PVH and PVL. PVH is for high voltage generation system (more than 500V and less than 1000V) and PVL is for the system less than 500V.

  • Insulation Resistance Tester for PV (2 range)

    MIS-PV1 - MULTI MEASURING INSTRUMENTS Co., Ltd.

    The model MIS-PV1 is an insulation resistance tester for the exclusive use in photovoltaic systems. The ordinary insulation resistance testers cannot make measurement properly during generation of PV systems. This instrument, however, can measure the insulation resistance simply by touching probe to the live line whether making generation or not. There are two ranges of PVH and PVL. PVH is for high voltage generation system (more than 500V and less than 1000V) and PVL is for the system less than 500V.

  • Universal Power Supply

    TestVonics, Inc.

    TestVonics power supplies deliver clean, regulated AC power in a 3.5” high bench top or optional rackmount unit. The TVCS-PS-P1350 model has a fixed output of 115V 400Hz Single phase, ideal for testing the TTU-205 Test Sets. The TVCS-PS-1351 model has a variable output with selectable frequency (50/60/400 Hz) and voltage output for testing of a variety of test equipment including the TTU-205 and other air data test sets.

  • Field thermal needle system for thermal resistivity / conductivity measurement

    FTN01 - Hukseflux Thermal Sensors B.V.

    The FTN01 Field Thermal Needle System allows performing fast, on-site measurements of the thermal resistivity or conductivity of soils, in particular around the typical depth of burial of high voltage cables. FTN01 is designed with a focus on robustness and saving time, while still offering sufficient accuracy for typical field measurements. The sensor is a Non-Steady-State Probe (NSSP), TP09, which is mounted at the tip of the Lance LN01. The system is operated using a hand-held Control and Readout Unit CRU01.

  • Connector Test

    Applied Relay Testing Ltd.

    A connector test system which provides expansion of up to 160 Kelvin pair connections. The system incorporates high voltage AC and DC power supplies with a maximum output of +/- 2100 Volts peak for Hi Pot, Insulation resistance measurement. LCR bridge control is provided with 4 terminal multiplexing in order to add precision capacitance, inductance and resistance measurement capability. An integral H.V. capacitor bias option permits capacitance measurement to be made at up to 2.1kV.

  • Measurement System for ESD Protection

    SampleProtect - Oxford Instruments plc

    The SampleProtect measurement system is ready to go, and comes complete with Oxford Instruments’ Cryofree bottom loading cryostat – the OptistatDry BLV, Zurich Instruments’ MFLI Lock-in Amplifier, a specially designed ESD break-out box and high quality measurement grade cables. The patent-pending puck style mounting from Oxford Instruments provides safe installation of your samples. The MFLI 500 kHz Lock-in Amplifier (capable of 500 kHz demodulation as standard) with MF-MD multi-demodulator capability brings the benefits of high performance signal processing at low and medium frequencies. The differential voltage and current inputs of the MFLI are optimised for low noise operation and the high oversampling rate ensures an even better signal to noise ratio. Zurich Instruments’ unique LabOne® control software provides a toolset including an integrated oscilloscope, a spectrum analyser, a plotter and a parameter sweeper.

  • Phasing Voltmeter/Sensor (2 in 1)

    STB Electrical Test Equipment, Inc

    STB unit replaces 3 separate units manufactured by competitors - line phasing, capacitance phasing and line to ground Versatile, lightweight and easy to useEach portable meter has a single rangeMeter usage: Voltage detection and phasing at capacitance test points or voltage detection and phasing on bare energized conductors (overhead & underground)Probes can be separated to be used as a voltage sensor or capacitance sensorFive position selector switch used to select voltage sensing on capacitance tap or direct line and phasing on capacitance tap, direct line or a battery test positionNo exposed conducting terminals or meter circuitryLocking cable connector provides positive contactScale is large enough to be easily read 8'-10' when mounted on a suitable hot stickLine to ground voltage readings are accurate within 3% at full scaleMaximum operating temperature range -20°F to 165°F (-30°C to 75°C)25' coiled cable includedAccessoriesMODELDESCRIPTION50118-G-10Hot Sticks (full set - 6)10104-P-02Shepherd's Hook10104-P-03Probe Tip30142-P-01Shot Gun Adapter50111-P-01Regular Bushing Adapter10275-P-01Universal AdapterModelsMODELDESCRIPTIONWeight50101-G-07Phasing Voltmeter 9-36kV16 lbs.50101-G-08Phasing Voltmeter 9-36kV with Hot Sticks (full set - 6)21 lbs.Request QuoteOperating Instructions9-36kV Phasing VoltmeterProduct Summary/OptionsProvides safe and convenient testing means for paralleling 3-phase high voltage circuitsConsists of two resistance elements connected in series with an indicating meter in the series connectionTwo ranges, 9kV and 36kV, with a range selector switch mounted on the back of the meter housingSwitch is clearly marked for the range of the voltmeterTypical use: Line-to-ground voltage measurements and phase for paralelling operationsScale markings on the voltmeter have a minimum of divisions and the figures are large enough to be easily read 8'-10' away when mounted on a suitable hot stickInput impedance: Approximately 72 megohmsMaximum operating temperature range -20°F to 165°F (-30°C to 75°C)Ready to attach on hot stick10' cable, a proof tester, battery and shepherd’s hook and probe tip includedOperating InstructionsRequest QuoteOperating InstructionsModelsMODELDESCRIPTION50100-G-010-2kV DC Voltmeter 30’ cable, magnetic track adapter50100-G-020-1500kV DC Voltage Meter50100-G-030-1500kV DC Voltage Meter with Hot Sticks50100-G-04DC Voltmeter 1500kV DC w/Extension Probe and Ground Lead50100-G-050-1500V DC with Hot Sticks and Lighted Dial50100-G-060-1500 DC Voltage Meter with Lighted DialDC Voltmeter​Product Summary/OptionsLightweight, easy to use, hand-held meterHard wired unit Scaled 0-1500vDC, in 100 volt incrementsProvides a 2/3 full scale deflection when applied across 1000vDCMaximum current flow through instrument at 1000vDC is 0.05 milliampersNo polarity, sensitivity issuesMay be used to determine whether the third rail of a transit system is energizedInput impedance of approximately 24 megohmMaximum operating temperature range -20°F to 165°F (-30° C to 75°C) Request QuoteAC VoltmeterProduct Summary/OptionsTwo-position toggle switchPortable instrument for quickly and easily measuring AC voltages Locking cable connector provides positive, electrical contactResistive voltmeter - medium range voltage measurements in the fieldTypical use - measure voltage between ground and the line or bus connector20' ground lead includedInput impedance - approximately 36 meghomsMaximum operating temperature rangeAccuracy of +/- 3% full scaleShare to TwitterShare to FacebookShare to PrintShare to EmailMore AddThis Share options

  • High Temperature, Low Strain Capacitive Extensometers (1200 C or 1600 C)

    Model 3648 - Jinan Testing Equipment IE Corporation

    These extensometers use a high temperature capacitive sensor in combination with an innovative design to achieve high accuracy strain measurements in low measuring ranges not possible with other high temperature extensometers. They mount on a slide bracket (included) that can attach to the load frame of your test system; optional load frame mounting brackets are available. The overall design reduces any influence from common lab environment vibrations.The standard temperature version (to 1200℃) is supplied with high purity alumina rods. The high temperature option is furnished with alpha grade silicon carbide rods. Rods are made to order to the length required for your furnace. These units are made to order in many different gauge lengths and measuring ranges.The extensometer comes with a signal conditioner. The output is an analog DC voltage, factory calibrated with the extensometer to 0 to ±10 VDC typically. They are readily interfaced with most existing test controllers, and may be directly connected to data acquisition systems and chart recorders. Bringing the signal into a spare DC input channel (or external input) on the test controller allows the extensometer to be used for strain controlled tests like low cycle fatigue.

Get Help